Modeling tool
Measure
Inspect edge and face geometry, the minimum gap between two exact solid bodies, and world-Z height and ground clearance.
Purpose
Inspect edge and face geometry, the minimum gap between two exact solid bodies, and world-Z height and ground clearance.
Where to find it
In Model, open Inspect and choose Measure.
Selection
- Geometry: tap body edges or faces to add or remove them from the measurement set.
- Distance: choose two different exact solid bodies using Body and Reference Body. You can also tap the bodies in the viewport, first the body then its reference.
- Height: choose one exact solid using Body or tap it in the viewport. Named menus use the same names as Bodies; STL reference meshes, sheets, and wires are excluded.
Steps
- Choose Measure, then Geometry, Distance, or Height.
- For Geometry, select edges or faces. Read Length, Total Length, Radius, Diameter, Area, Total Area, Perimeter, Center, or Axis Origin where available. With two items, Center Distance reports their representative centers or edge midpoints; it is not minimum clearance.
- For Distance, choose Body and Reference Body and wait for Minimum Distance. This is the shortest exact gap; touching, intersecting, or contained solids report zero.
- For Height, choose Body. Height is the current solid’s vertical extent along world Z. Ground Clearance is its lowest Z coordinate relative to the Z=0 ground plane, and can be negative.
- Use Clear to reset the active measurement selection, or Done to leave Measure.
Options
Result
Read-only measurements use the current project geometry and document units and precision. No History feature is added.
Editing
Body measurements refresh when the model changes. Geometry measurements follow the selected topology; select it again if an edit replaces it.
Troubleshooting
The reported distance differs from the spacing between centers.
Use Distance for minimum clearance between solids. Geometry → Center Distance compares representative centers or midpoints and is a different measurement.
Height differs from the original box Height parameter, or clearance is negative.
Height uses the current world-Z extent after rotation and scale. Ground Clearance uses the Z=0 plane; a negative result means the solid crosses below that plane.
A body is missing from a menu or exact measurement fails.
Select a current solid CAD body rather than an STL reference mesh, sheet, or wire. Resolve failed or suppressed upstream History before measuring. An unavailable exact result is shown as an error rather than an approximate mesh value.